Filament Tuning
Purpose
Flow calibration ensures that your printer's extruder accurately dispenses material, improving print quality.
Prerequisites
Klipper firmware installed and configured.
Printer connected and set up.
Basic printer calibration (such as axis calibration) completed.
Steps
1. Preparation
Confirm Printer Temperature: Ensure the hotend is heated to the appropriate printing temperature for your material. For PLA, set the hotend to around 200°C.
Check Nozzle: Ensure the nozzle is clear and not clogged.
Mark Material: Use a segment of material and make a mark at 100mm from the extruder gear.
2. Positioning and Extrusion
Home the Printer: Home all axes to ensure the printer is in the correct starting position. This will move the print head to the center of the build plate, making it easier to observe.
Extrude Material:
First Extrusion: Send the following command to extrude 50mm of material:
Second Extrusion: Immediately follow with another command to extrude another 50mm:
Measure: After the two extrusions (totaling 100mm), measure the total length of material extruded from the mark you made. The total length should ideally be around 100mm.
3. Adjust rotation_distance
Calculate New
rotation_distance
:If the actual total extrusion length deviates from the expected 100mm, use the following formula to calculate the new
rotation_distance
:
For example:
Old
rotation_distance
: 22.6789511Target length: 100mm
Actual extruded length: 98mm
Using the formula:
Update Configuration File:
Edit the
printer.cfg
file and update therotation_distance
with the new value:
4. Save and Restart
Save Configuration: Save changes to the
printer.cfg
file.Restart Klipper: Restart Klipper to apply the new configuration.
5. Verify
Retest: Perform the extrusion steps again to ensure the actual extrusion length matches the expected 100mm.
Adjust: Continue adjusting
rotation_distance
as needed until the extrusion is accurate.
Notes
Perform flow calibration after the hotend temperature has stabilized.
Ensure that the material used is consistent to avoid calibration errors due to material differences.
Keep a record of each
rotation_distance
adjustment for tracking and troubleshooting.
Last updated